Sikalastic HLM 5000 GC, Liquid, Cold-Applied Elastomeric Waterproofing Membrane, 5 Gallon Pail

Sikalastic HLM 5000 GC, Liquid, Cold-Applied Elastomeric Waterproofing Membrane, 5 Gallon Pail

$269.89
  • SKU: SIK 807634
  • UPC: 850069282103
  • Availability: Same Day Shipping If Ordered by 2 PM EST Monday to Friday
  • Shipping: Free Shipping
Availability: Same Day Shipping If Ordered by 2 PM EST Monday to Friday
In Stock & Ready To Ship!
Current Stock:Only left:
Description

Sikalastic® HLM 5000 GC is a one-component, moisture curing, bitumen-modified polyurethane elastomeric
waterproofing membrane for exterior below-grade or between slab applications.

  • Application on green or damp concrete
  • ́ Single component
  • ́ Innovative and proprietary formulation
  • ́ Low VOC
  • ́ Strong chemical resistance and elastomeric properties
  • ́ Suitable for wide temperature range

Applications

APPLICATIONS

  • Foundation walls
  • Between slabs
  • Bridges and tunnels
  • Plaza Decks
  • Planters
  • Split Slab, Pavers

Benefits & Uses

BENEFITS

  • Green concrete application
  • Available in standard and high-build system
  • Accommodates expansion and contraction
  • High chemical resistance to select acids, alkalis and salts
  • Does not require hot-melt equipment
  • Compliant with ASTM C836
  • Available with up to a 20 year warranty

Uses

  • Concrete
  • Plywood (exterior)
  • Exterior below grade (on masonry, concrete, and incidental metal)
  • Above grade (between two-course concrete and within cavity walls)
  • Parking garages
  • Plaza decks and malls
  • Balconies and planters
  • Below-grade slabs
  • Foundation walls
  • Walls and culverts
  • Split slabs

Characteristics

Characteristics / Advantages

  • Sikalastic® HLM 5000 GC can be applied minimum 72 hrs after the concrete is poured, or as little as 24 hrs following the removal of the forms.
  • Can be applied to damp concrete
  • Available in standard and high-build systems to prevent water penetration
  • Passes ASTM C 1305
  • Elastomeric product accommodates expansion and contraction
  • Wide service-temperature range, making Sikalastic® HLM 5000 GC suitable for all climates
  • Chemical resistance to bacterial attack, select acids, alkalis and salts
  • Seamless cold-applied membrane eliminates lapping, seaming and precutting
  • Does not require hot-melt equipment
  • Compliant with ASTM C 836
  • Compliant with national standard of Canada 37.58 - M86 developed by CGSB
  • Compliant with SCAQMB

Product Information

PRODUCT INFORMATION

Chemical Base Bitumen-modified polyurethane
Packaging 5 gal (19 lts) pails
Color Black
Shelf Life 12 months
Storage Conditions Store in unopened containers in clean, dry, conditions at +40 °F to +80 °F
°C to +27 °C). During storage, an easily removable skin of Sikalastic® HLM 5000 GC may form, which
does not affect performance of the product.

Thickness
60 mils Approx. 25 ft2/gal at 60 mils DFT
90 mils Approx. 18 ft2/gal at 90 mils DFT
120 mils Approx. 13 ft2/gal at 120 mils DFT
Note: Coverage may vary with the application technique used. Actual coverage rate and mil thickness
depend on finish and porosity of the substrate.

Volatile organic compound (VOC) content
RG: 53 g/L

Viscosity 800 poise Brookfield
Solid content by mass 85% ± 1%
CSI / CSC MasterFormat® 07 14 00 Fluid-Applied Waterproofing

Technical Information

TECHNICAL INFORMATION

Testing 120 mil (High-Build) 60 mil (Standard) N/A 85
ASTM C 836 (Type OO)

Tensile Strength 120 mil (High-Build) 60 mil (Standard) 200 psi (1.4 MPa) 150 psi (1.0 MPa)
ASTM D 412

Elongation at Break 120 mil (High-Build) 60 mil (Standard) 300% 600%
ASTM D 412
(Elongation)

Dimensional Stability Weight Loss
120 mil (High-Build) 16%
60 mil (Standard) 16%
ASTM C 836

(20% maximum)
Crack Bridging Ability 120 mil (High-Build)
60 mil (Standard)
ASTM C 1305

Passed 1/4"
no loss of bond or cracking exhibited

Passed 1/16"
no loss of bond or cracking exhibited

cycled 10 times per 24 hrs at +15 °F (- 9°C)

Water Vapor Transmission 120 mil (High-Build) 60 mil (Standard
0.075 perms 0.1 perms

ASTM E96

Service Temperature min. - 40 °F (- 40 °C) / max. + 120 °F (+50°C)
Adhesion in peel 120 mil (High-Build) 60 mil (Standard) min. 5 lbs/in min. 5 lbs/in

ASTM C 836

Dimensional change after immersion in water

None (after 3 days at +73 °F / +23 °C)

Thermal resistance 120 mil (High-Build) 60 mil (Standard) No cracking No cracking

ASTM C836

Application Instructions

LIMITATIONS

  • Apply Sikalastic® HLM 5000 GC when substrates are dry and air temperatures are +40 °F to +90 °F (+4 °C to +32 °C); for application at temperatures below +40 °F (+4 °C), consult Technical Services.
  • Temperatures influence viscosity and handling characteristics of Sikalastic® HLM 5000 GC : heat increases and cold decreases the flow. Keep Sikalastic® HLM 5000 GC cool in hot weather and warm in cold weather. Avoid application when inclement weather is present or imminent.

SURFACE PREPARATION

  • All concrete deck surfaces should be lightly steel troweled to a flat uniform surface. A light broom finish is acceptable. Membrane curing compounds must be mechanically removed.
  • For extremely porous block: Prime substrate with Sikadur-22 Lo-Mod FS, Sikalastic FTP Lo-VOC Primer or Sikalastic GDC Primer.
  • Remove dust, dirt and other contaminants just before application. Surfaces must be dry at the time of application.
  • Air-void pockmarks or honeycombs must be opened up to allow Sikalastic® HLM 5000 GC to fill the cavities completely. Air entrapment within voids may cause blisters. Extreme cases may require additional repair.

PRESTRIPING

  • Before applying the final membrane, all joints, cracks and openings around protrusions must be sealed by caulking or prestriping (a preliminary coating of Sikalastic® HLM 5000 GC applied with a trowel or stiff- bristled brush) as outlined in section "Static Joint and Cracks". Allow to dry overnight before applying final membrane.
  • When the final membrane is applied, the overall thickness over joints and cracks, at coves and around penetrations should be approximately 100 wet mils (2.5 mm) on the standard system.

STATIC JOINTS AND CRACKS

Joints and cracks less than 1⁄16" (1.6 mm) should be filled by prestriping. Apply material so it both fills and overlaps the joint or crack to a width of 4" (102 mm) on each side.

CONSTRUCTION OR EXPANSION JOINTS

All joints over 1⁄8" (3 mm) must be sealed with Sikaflex®-1A or Sikaflex®-11 FC. Any working joint less than 1⁄8" (3 mm) should be routed to a minimum of 1/4" (6 mm) and filled with a sealant. Prevent the waterproofing membrane from adhering to the joint sealant, which could cause sealant or membrane failure, by applying a coat of wax or bond breaker tape over the cured sealant and then prestriping.

UNCOATED METAL SURFACES

Remove dust, debris, and any other contaminants from vent, drain pipe and post penetrations, reglets and other metal surfaces. Clean surfaces to near white per SSPC- NACE2 and prime immediately with Sikadur-22 Lo-Mod FS or Sikalastic EP Primer. Provide appropriate cant with Sikaflex®-1A or Sikaflex®-11 FC sealants to eliminate 90° angles.

VENT, DRAIN PIPE, AND POST PENETRATIONS

Clean metal surfaces to bright metal and prime with metal primer Sikadur-22 Lo-Mod FS or Sikalastic EP Primer. Remove dust, debris and any other contaminants from voids. Seal with the appropriate sealant. For PVC substrates use Sikaflex® Primer-449.

APPLICATION

A test application is always recommended before proceeding with entire application.

NOTE: Finish coat must be applied in a pinhole-free, continuous membrane for waterproofing integrity. STANDARD SYSTEM

  • For horizontal applications, empty contents of pail and spread immediately to ensure workability. Best results are obtained by marking off 125 ft2 (11.61 m2) areas and evenly spreading the contents of a 5 gallon (18.93 L) unit with a rubber-edged notched squeegee. Repeat the above procedure until the entire surface is covered.
  • For vertical applications, apply by brush or roller at the rate of 25 ft2/gallon (0.6 m2/L). Best results are obtained by marking off 125 ft2 (11.6 m2/L) and evenly applying the contents of a 5 gallon (18.93 L) pail.
  • Verify the applied thickness with a wet mil gauge as the work progresses.
  • The integrity of the cured membrane on a horizontal surface may be verified by damming the entire area and flooding with water to a minimum depth of 2" (51 mm) and allowing the water to stand for 24 - 48 hours. Visually inspect the bottom surface to check for any water penetration. If repairs are necessary, the area should be drained and allowed to dry before reapplying Sikalastic® HLM 5000 GC. After reapplication, the area should be tested again for membrane integrity.

HIGH-BUILD SYSTEM

  • Concrete application: Apply 60 wet mils of Sikalastic® HLM 5000 GC. Allow the first coat to cure overnight and follow with a second 60 wet-mil application of Sikalastic® HLM 5000 GC.
  • Plywood/OSB board application: All plywood construction must comply with APA (American Plywood Association) standards. All plywood/OSB board joint must be sealed Sikaflex®-1A or Sikaflex®-11 FC. A detail coat of the membrane must be applied before the final membrane is installed.

CURING

Appreciable properties develop within 24–48 hours at 75 °F (24 °C) and 50% relative humidity. Protect Sikalastic® HLM 5000 GC from traffic during curing.